%0 Generic %A Klok, E.J. %A Kluck, J. %D 2018 %T Data Zuidas Amsterdam.xlsx %U https://uvaauas.figshare.com/articles/dataset/Data_Zuidas_Amsterdam_xlsx/5827914 %R 10.21943/auas.5827914.v1 %2 https://uvaauas.figshare.com/ndownloader/files/10312854 %K air temperatures %K urban heat island %K Amsterdam %K Measurements %X The dataset exists of air temperature data measured at 15 locations on the Zuidas in Amsterdam between 24 June and 7 October 2016. The coordinates of the locations are given in the spread sheet.

Sensors TRH1 and TRH2 are TinyTag TV-4505 data loggers with an external probe. The temperature is measured by a 10k NTC thermistor. Sensors T01-T13 are TinyTag TV-4020 data loggers with an external probe. This probe also uses a 10k NTC thermistor to measure the temperature. The resolution of the 10k NTV thermistor is 0.02 ÂșC.

All probes were installed in a radiation shield (M & R model 511-10). The scan speed was 1Hz. Every 5 minutes the average temperature was stored.

The sensors were attached to lamp posts, the measuring height of which was between 3.5 and 4 meters. The sensors were mounted on the north side to minimize the influence of solar radiation.
%I University of Amsterdam / Amsterdam University of Applied Sciences